Request Quote
superlite-ii-xlm-90-e

Framing Options

Features

  • Fire resistive multilamintate glazing offering maximum fire and safety with hose stream for 90 minute wall and door applications.
  • Meets ASTM E-119 for full radiant heat protection and CPSC Cat. II (400 ft. lbs.) impact safety requirements.
  • Can be used in interior and exterior applications.
  • Optically clear glazing without wires or tints.
  • Available in custom architectural make-ups including energy-saving insulated units, decorative, security and more.
  • Can be easily incorporated in GPX Architectural Series Framing, GPX SNAPCAP or GPX Builders Series Temperature Rise Framing for a complete fire rated assembly.
  • 5 year manufacturer’s warranty.
  • Fabricated in the U.S.A. for fast lead times.
Fire Rating Application Max CV Area Max CV W Max CV H Stops
90 minute Doors 2,916 in.² (1.88 m²) 36 in. (0.91 m) 61 in. (1.55 m) 5/8 in. (16 mm)
90 minute Walls (with framing & butt-glazed) 3,828 in.² (2.47 m²) 88 in. (2.24 m) 88 in. (2.24 m) 1 in. (25.4 mm)

Specifications

  • Thickness:1-3/8 in (35 mm) interior
  • Weight: 14.15 lbs./sq.ft. (69 kg/m²) In 1-3/8 In. (35 mm) interior
  • Sound Reduction: Rw = 43 dB
  • Fire Rating: 90 minutes with hose stream. Meets ASTM E119 and NFPA 251 and UL 263
  • Impact Safety Rating: CPSC 16 CFR 1201 Cat. I and II, ANSI Z97.1
  • Light Transmission: 82%
  • R-value: 1.16
  • U-value: 0.882

Listings and warranty

SuperLite II-XLM is listed and labeled by Intertek and Underwriters Laboratories, nationally recognized testing laboratories approved by OSHA.

  UL-Logo

Standards

UL 9, UL 10B, UL 10C, UL 263, NFPA 80, NFPA 251, NFPA 252, NFPA 257, ASTM E119, ASTM E152, ASTM E163, ASTM E2074, ASTM E2010-01, CPSC 16 CFR 1201 Cat. II, ANSI Z97.1, ULC CAN4-S101, ULC CAN4-S104, ULC CAN4-S106.

Do you have a current or upcoming project that needs fire rated glass and framing? Contact us today!