Skip to content
  • QUOTE
  • 888.653.3333
  • info@safti.com
  • Products
    • Fire Protective Glass Tested to NFPA 252/257, UL 9/10C, ULC S104/S106; Blocks smoke and flames.
    • SuperLite® I
    • SuperClear® 45-HS
    • SuperClear® 45-HS-LI
    • SuperLite® I-XL
    • SuperLite® I-XL IGU
    • SuperLite® X-45/60/90
    • SuperLite® II-XL 45
    • Ceramics
    • Fire Resistive Glass Tested to ASTM E119 / UL 263 / ULC S101; Blocks smoke, flames and radiant heat.
    • SuperLite® II-XL 60
    • SuperLite® II-XL 90
    • SuperLite® II-XL 120
    • SuperLite® II-XLB 60
    • SuperLite® II-XLB 120
    • SuperLite® II-XLM 60
    • SuperLite® II-XLM 120
    • SuperSecure® II-XLS 45-120
    • Fire Rated Walls 60-120 minute fire resistive glass and frame assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® Architectural Series Fire Resistive
    • GPX® Curtain Wall
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Blast System
    • GPX® EZ Frame
    • Fire Rated Doors Full vision 20-45 minute fire protective doors and 60-90 minute temperature rise doors tested to NFPA 252 / UL 10C / ULC S104.
    • GPX® Architectural Series Fire Protective
    • GPX® Architectural Series Fire Resistive
    • GPX® Builders Series Fire Protective
    • GPX® Builders Series Temperature Rise
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Vision Kit
    • Fire Rated Openings 20-45 minute fire protective glass and framing assemblies tested to NFPA 257 / UL 9 / ULC S106.
    • GPX® Architectural Series Fire Protective
    • GPX® Builders Series Fire Protective
    • GPX® EZ Frame
    • Fire Rated Floors 60-120 minute fire resistive glass floor assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® FireFloor
    • Fire Rated Fences 20-60 minute fire rated glass fence for WUI areas or designated fire zones.
    • SAFTI FENCE
    • Specialty Glass
    • Laminated Safety Glass
  • Literature
  • Specs
  • Details
  • Videos
  • Resources
    About Us
    Videos
    Case Studies
    Articles
    Blogs
    Continuing Education
    Literature
    BIM Library
    Industry Links
    Press Releases
    Testimonials
    Technical Bulletins
    Newsletters
    Product Selector
  • Gallery
  • Contact
    Contact Us
    Meet Our Team
    Find Your Local Rep
    Request a Quote
  • Products
    • Fire Protective Glass
    • Fire Resistive Glass
    • Fire Rated Walls
    • Fire Rated Doors
    • Fire Rated Openings
    • Fire Rated Floors
    • Fire Rated Fences
  • Literature
  • Specs
  • Details
  • Videos
  • Resources
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Literature
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Contact
    • Contact Us
    • Meet Our Team
    • Find Your Local Rep
    • Request a Quote
Menu
  • Products
    • Fire Protective Glass
    • Fire Resistive Glass
    • Fire Rated Walls
    • Fire Rated Doors
    • Fire Rated Openings
    • Fire Rated Floors
    • Fire Rated Fences
  • Literature
  • Specs
  • Details
  • Videos
  • Resources
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Literature
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Contact
    • Contact Us
    • Meet Our Team
    • Find Your Local Rep
    • Request a Quote
Articles
Code Education
Code Update: What Architects Need to Know About AC 385
Code Education

Code Update: What Architects Need to Know About AC 385

BySAFTI FIRST Team
| March 27, 2015

What Architects Need to Know About AC 385

This timely code update article explains what architects need to know about AC 385 before considering using special-purpose sprinklers in lieu of fire resistive glazing assemblies. 

In February 2015, the ICC-ES Evaluation Committee agreed to adopt a modified AC 385 which allows an exemption for “special-purpose sprinklers used with fixed glass assemblies” as fire barriers in exit passageways, horizontal exits or exit enclosures when the fire area is fully sprinklered, and if the use is approved by an AHJ as described in Sections 104.10 and 104.11 of the IBC 2012. Before rushing out to specify fixed glass assemblies with special purpose sprinklers in lieu of fire resistant glass, there are important issues that every architect and specifier need to consider.

AC 385 Explained

The ICC-ES first adopted AC 385 in October 2007 at the behest of a major manufacturer of sprinkler heads. In 2011, the ICC-ES Evaluation Committee issued a memo to withdraw its Criteria for this alternative in lieu of building materials tested to ASTM E-119. The 2012 IBC (Section 703.4) specifically states that the “fire-resistance rating of a building element, component or assembly shall be established without the use of automatic sprinklers or any other fire suppression system being incorporated as part of the assembly tested in accordance…[with] ASTM E 119 or UL 263.” Click here to read more about the origins of AC 385.

AC 385 was revised in February 2013 to try to extend the exception for use the fixed glass assemblies with special purpose sprinklers, but prohibit their use in lieu of firewalls and fire barriers (Section 5.1.11). In October 2014, a proposal to allow this alternative to be used as internal fire barriers or exterior walls was defeated. In February 2015, a new modified AC 385 was adopted that reauthorizes the use of this alternative as a fire barrier.

AC 385 Requires Prior AHJ Approval

Using special-purpose sprinklers in lieu of fire resistive glazing assemblies requires prior approval from the authority having jurisdiction. Section 104.10 of the 2012 IBC clearly addresses that a waiver of code requirements is to be considered “Wherever there are practical difficulties involved in carrying out the provisions of this code, the building official shall have the authority to grant modifications for individual cases, upon application of the owner or owner’s representative, provided the building official shall first find that special individual reason makes the strict letter of this code impractical and the modification is in compliance with the intent and purpose of this code and that such modification does not lessen health, accessibility, life and fire safety, or structural requirements.”

It would be helpful to know what typical practical difficulties exist that would justify the implementation of AC385 given that fire rated glazing and framing systems are readily available, less costly, and fully code compliant. Neither supportive submittal mentioned any specific practical difficulty being overcome by virtue of AC385.

AC 385 Does Not Address Sprinkler Failure

Fact is, sprinklers can and do fail. According to NFPA’s Report U.S. Experience with Sprinklers in June 2013, “Sprinklers operated in 91% of all reported structures large enough to activate sprinklers… When sprinklers operated, they were effective 96% of the time, resulting in a combined performance of operating effectively in 87% of all reported fires where sprinklers were present in the fire area and the fire was large enough to activate them.”

In the same NFPA report, majority of sprinkler failures (where sprinklers did not activate at all) occurred because the system was shut off, and that majority of sprinkler ineffectiveness (where sprinklers activated but were not effective) was because water did not reach the fire or not enough water was released. This could be caused by a number of factors, including manual tampering, lack of maintenance, low water pressure or damage to the system, which is a real possibility during natural disasters such as earthquakes. FM Global reported “sprinkler system breakage puts your fire protection out of service at the time that you need it the most. After an earthquake, the threat of fire is greater due to the increased presence of ignition sources and, at some facilities, flammable material releases.”

So in the case of the alternate glazing system covered by AC385, its potential effectiveness is entirely dependent on 100% sprinkler reliability and effectiveness, which doesn’t exist because as the NPFA report demonstrates that potential for failure is always present. On the other hand, fire resistive glazing assemblies provides built-in life and property protection 24 hours a day, 7 days a week without the mechanical triggers that sprinklers need, which makes it 100% reliable, effective and virtually maintenance-free.

AC 385 Does Not Protect From Radiant Heat

The most important benefit of incorporating fire resistive glazed assemblies is the fact it is best defense against dangerous radiant heat, invisible electromagnetic waves that travel at the speed of light with little resistance. When these waves strike an object, they are absorbed and their energy is converted to heat. If the object is a combustible material, a fire will start when the material´s ignition temperature is reached. Radiant heat is extremely dangerous to building occupants since it can quickly reach a level that causes unbearable pain, followed rapidly by second degree burns, preventing safe egress.

AC 385’s alternate glazing assembly incorporates non-rated glazing and a mechanically-triggered water curtain delivered by special purpose sprinklers. When the sprinklers fail to operate, the non-rated glass will be useless in preventing fire, smoke and dangerous radiant heat. In contrast, fire resistive glazed assemblies are tested and certified to meet ASTM E-119, do not need mechanical triggers and readily available without needing prior AHJ approval.

AC 385 Has Hidden Costs

Like most decisions related to construction materials, cost could be one contributing factor why a designer might opt to pursue AHJ approval for
Special purpose sprinklers with fixed non-rated glazing instead of a listed and labeled fire resistive glass assembly. Before assuming that AC 385 is a cheaper solution, here are some things to consider. The cost of design and installation of these special purpose sprinklers and non-rated glass assemblies is just one aspect. There are costs during the life of the building related to sprinkler maintenance, construction and upkeep of water mains to sustain water pressure in the special purpose sprinkler pipes and pipe maintenance. Finally, there are costs associated with loss of life and property in the event of a fire where the sprinklers fail to activate and radiant heat transmission is not controlled.

Design Considerations

Last but not least, there are design elements and aesthetics that architects need to consider. Here is an example of what AC 385 looks like after obtaining AHJ approval:

Code Update: What Architects Need to Know About AC 385

Here’s what an ASTM E-119 rated, listed and labeled fire resistive glazed assembly looks like, without having to obtain AHJ approval:

Code Update: What Architects Need to Know About AC 385
ASTM E-119 rated SuperLite III-XL Butt-glazed in GPX Architectural Series perimeter framing.

As you can see, using fire resistive glazing eliminates the need for unsightly pipe fixtures and sprinkler heads directly above the glass. Fire resistive glazing also allows for floor-to-ceiling and wall-to-wall expanses of glass, with butt-glazing as an available option as well.

So before embarking on obtaining AHJ approval for AC 385 in lieu of readily available, fully code-compliant fire resistive glazing assemblies, make sure that you’ve considered the risks, hidden costs and aesthetic limitations that AC 385 presents because in the end, you might be trading-off fire safety without even knowing it.

Share:
PrevNext ArticleFire Safety Should Never Be Sacrificed
Previous ArticleCodes for Hurricane Rated GlazingNext
Back to Articles

Engineering. Design. Code.

Whether you’re looking for fire-rated walls, doors, openings, floors or a specialty service, we have the solution for you. With over 40 years of experience in testing, innovating, and providing technologically advanced fire-rated glass and framing products, we deliver unyielding performance and quality at a competitive price.

Let's Talk!

  • 888.653.3333
    (English)
  • 888.653.3333 ext. 652
    (Spanish)
  • info@safti.com
  • Representative Map
Contact
Phone
888.653.3333 - English
888.653.3333 ext. 652 - Spanish
Fax
888.653.4444
Email
info@safti.com
Address
Corporate
100 N Hill Dr, Ste12, Brisbane, CA 94005
Factory
220 S R Street, Merced, CA 95341

Sign up for our Newsletter!

Get notified of industry updates and new product alerts.

AFFILIATE COMPANIES
Division 5
1850 Grogan Ave, Merced, CA 95341
888.653.3333
Division 8
1891 Wardrobe Ave, Merced, CA 95341
866.848.2667
© 2025 SAFTI FIRST. All rights reserved.​
Disclaimer & Privacy Policy | Cookie Policy
Instagram Linkedin Facebook Youtube Vimeo
Suggested Pages
Case Studies
Request a Quote
SuperClear® 45-HS-LI
Continuing Education
Request a Quote
Continuing Education
Videos
SuperClear® 45-HS-LI
Case Studies
This website uses cookies to ensure you get the best experience on our website.

This website uses cookies to ensure you get the best experience on our website.


This website uses cookies to improve user experience. A cookie file is stored in your web browser and allows the website to recognize you and make your next visit easier and the website more useful to you. By using our website, you consent to all cookies in accordance with our Cookies Policy. Learn more.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage vendors Read more about these purposes
View preferences
{title} {title} {title}