Request Quote
Fire Rated Glass
Glazing Features Applications
SuperLite IFire Protective Specialty Tempered

20 minute, CPSC Cat. II, clear specialty tempered glazing. Decorative options also available.

Fire protective doors and partitions.

SuperLite I-XLFire Protective Specialty Tempered with Partial Radiant Heat Protection

20-45 minute, CPSC Cat. II, directional clear specialty tempered glazing with partial radiant heat protection.

Fire protective doors, sidelites, windows and transoms.

SuperLite I-XL does not meet ASTM E119 and requires AHJ approval for 45 minute applications. Click here for more information.
SuperLite I-XL IGUFire Protective Specialty Tempered with Partial Radiant Heat Protection

20-45 minute, CPSC Cat. II, bi-directional clear specialty tempered glazing with partial radiant heat protection.

Fire protective doors, sidelites, windows and transoms.

SuperLite I-XL IGU does not meet ASTM E119 and requires AHJ approval for 45 minute applications. Click here for more information.
SuperLite I-WFire Protective Wired with Safety Film

20-90 minute, CPSC Cat. II safety wired glazing.

Fire protective doors, sidelites, windows and transoms. 60-90 minute ratings are limited to 100 square inches in temperature rise doors, and up to the maximum size tested in non-temperature rise doors.

SuperLite X-45/60/90Fire Protective Door Lites up 100 sq. in.

45-90 minute clear, non-wired, and tint free glazing that meets all the fire and safety requirements for doors up to 100 square inches.

45/60/90 minute door vision lites limited to 100 square inches.

SuperLite II-XL 45Fire Resistive Tempered Glazing

45 minute, CPSC Cat. II, ASTM E119 tested, clear transparent glazing that blocks radiant heat transfer. Can be customized to include energy performance, noise abatement benefits, bullet resistance, hurricane resistance, and unlimited decorative options.

Fire protective doors, windows, openings and transoms.

SuperLite II-XL 60Fire Resistive Tempered Glazing

60 minute, CPSC Cat. II, ASTM E119 tested, clear transparent wall glazing that blocks radiant heat transfer. Can be customized to include energy performance, noise abatement benefits, bullet resistance, hurricane resistance, and unlimited decorative options.

Fire resistive doors, windows and wall assemblies.

 

SuperLite II-XL 90Fire Resistive Tempered Glazing

90 minute, CPSC Cat. II, ASTM E119 tested, clear transparent wall glazing that blocks radiant heat transfer. Can be customized to include energy performance, noise abatement benefits, bullet resistance, hurricane resistance, and unlimited decorative options.

Fire resistive doors, windows and wall assemblies.

SuperLite II-XL120Fire Resistive Tempered Glazing

120 minute, CPSC Cat. II, ASTM E119 tested, clear transparent wall glazing that blocks radiant heat transfer. Can be customized to include energy performance, noise abatement benefits, bullet resistance, hurricane resistance, and unlimited decorative options.

Fire resistive doors, windows and wall assemblies.

SuperLite II-XLBFire Resistive Tempered Glazing for Oversized and Butt-Glazed Applications

60-120 minute, CPSC Cat. II, ASTM E-119 tested, fire resistive tempered glazing that blocks radiant heat transfer.  Butt-glazed assemblies and other decorative glass make-ups available.

Fire resistive wall assemblies.

SuperLite II-XLM 45Fire Resistive Multilaminate Glazing

45 minute, CPSC Cat. II, ASTM E119 tested, clear fire resistive multilaminate glazing that blocks radiant heat transfer.  Can be customized to include energy-saving insulated units, decorative, security and more.

 

Fire protective doors, windows, openings and transoms

SuperLite II-XLM 60Fire Resistive Multilaminate Glazing

60 minute, CPSC Cat. II, ASTM E119 tested, clear fire resistive multilaminate glazing that blocks radiant heat transfer. Can be customized to include energy saving insulated units, decorative, security and more.

Fire resistive doors and wall assemblies. Available in butt-glazed applications.

SuperLite II-XLM 90Fire Resistive Multilaminate Glazing

90 minute, CPSC Cat. II, ASTM E119 tested, clear fire resistive multilaminate glazing that blocks radiant heat transfer. Can be customized to include energy saving insulated units, decorative, security and more.

Fire resistive doors , windows and wall assemblies.

SuperLite II-XLM 120Fire Resistive Multilaminate Glazing

120 minute, CPSC Cat. II, ASTM E119 tested, clear fire resistive multilaminate glazing that blocks radiant heat transfer. Can be customized to include energy-saving insulated units, decorative, security and more.

Fire resistive wall assemblies. Avaialble in butt-glazed applications.

SuperSecure II-XLS 45 to 120Fire Resistive Security Glazing

45-120 minute, CPSC Cat. II, ASTM E119 tested, clear transparent wall glazing that blocks radiant heat transfer and meets forced entry requirements.

Fire resistive doors, windows, and wall assemblies for prisons and other high security areas.

Pyran PlatinumFire Protective Non-safety Ceramic

20-90 minute, environmentally friendly ceramic glass free from tints and noticeable distortions without the added cost of polishing. No impact resistance..

Fire protective windows and transoms where human impact safety requirements do not apply.

Pyran Platinum FFire Protective Filmed Safety Ceramic

20-180 minute, environmentally friendly, filmed ceramic glass free from tints and noticeable distortions without the added cost of polishing. Impact safety rated to CPSC Cat. II.

Fire protective doors, sidelites and windows where impact is a concern. 60-180 minute ratings are limited to 100 square inches in temperature rise doors, and up to the maximum size tested in non-temperature rise doors.

Pyran Platinum LFire Protective Laminated Safety Ceramic

20-180 minute, environmentally friendly, laminated ceramic glass free from tints and noticeable distortions without the added cost of polishing. Impact safety rated to CPSC Cat. II.

Fire protective doors, sidelites and windows where impact is a concern. 60-180 minute ratings are limited to 100 square inches in temperature rise doors, and up to the maximum size tested in non-temperature rise doors.