SuperLite® I-XL IGU
20-45 Minute Fire Protective Glazing
Bi-Directional Without Hose Stream
FIRE PROTECTIVE - HEAT REFLECTIVE
Contains smoke and flames. Provides partial radiant heat protection.
Product Advantages
- Patented bi-directional specialty tempered glazing tested without hose stream, that provides low cost bi-directional partial radiant heat protection and insulation not available with ceramics.
- Accepted by the GSA and AHJ’s across the country as a safe and value added alternative to traditional unsafe wired glass and expensive ceramics.
- Received a General Approval from the City and County of Los Angeles ( RR25655).
- Meets the highest human impact safety requirements.
- Approved for 20 minute applications without limitations.
- Regularly specified for use in exterior applications and perfect for property line requirements.
- Acoustical value of 33 STC and available in specialty architectural make-ups.
- Standard 5 year limited warranty.
- USA manufactured for fast lead times and competitive pricing.
maximum sizes
Fire Rating | Application | Max. CV Area | Max. CV Width | Max. CV Height | Stops |
---|---|---|---|---|---|
20 Minutes | Wood or Steel Doors | 3,341 in.² (2.16 m²) | 35-1/8 in. (0.89 m) | 95-1/8 in. (2.42 m) | 5/8 in. (16 mm) |
20 Minutes | Steel Sidelites, Transoms and Windows/Openings | 3,522 in.² (2.27 m²) | 48 in. (1.22 m) | 96 in. (2.44 m) | 5/8 in. (16 mm) |
45 Minutes* | Wood or Steel Doors | 3,341 in.² (2.16 m²) | 35-1/8 in. (0.89 m) | 95-1/8 in. (2.42 m) | 5/8 in. (16 mm) |
45 Minutes* | Steel Sidelites, Transoms and Windows/Openings | 3,522 in.² (2.27 m²) | 48 in. (1.22 m) | 96 in. (2.44 m) | 5/8 in. (16 mm) |
*Requires AHJ approval for these applications because it is tested without hose stream.
Product Specifications
3/4 in. (19 mm) custom
listings and standards
SuperLite® I-XL IGU is listed and labeled by Underwriters Laboratories and Intertek, nationally recognized testing laboratories approved by OSHA.
Listings
- Intertek: 23754; 24569
Standards
- UL 9, UL 10B, UL 10C
- NFPA 80, NFPA 252, NFPA 257
- ASTM E152, ASTM E163, ASTM E2074, ASTM E2010-01
- CPSC 16 CFR 1201 Cat. II
- ANSI Z97.1
Related Case Studies
Learn more about fire rated glass and framing through our case studies. We highlight innovative design applications in real-world settings and show how architects continue to push the boundaries of what fire rated glass and framing can do.
After learning about the hazards of traditional wired glass and changes in the building code, MIddlebury College acted quickly to survey and catalogue every piece of traditional wired glass panel on campus. They created a spreadsheet noting the location and sizes of over 1500 pieces of traditional wired glass in doors and windows. Then, Middlebury set out to replace the wired glass with clear, safe, fire rated alternatives.